{"id":2378,"date":"2026-08-21T15:12:41","date_gmt":"2026-08-21T15:12:41","guid":{"rendered":"https:\/\/www.buffaloextracts.com\/knowledge\/?p=2378"},"modified":"2026-08-21T15:13:31","modified_gmt":"2026-08-21T15:13:31","slug":"ped-compliance-extraction-equipment","status":"publish","type":"post","link":"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/","title":{"rendered":"PED Compliance for Extraction Equipment: A Simple Guide"},"content":{"rendered":"<div class=\"vce-row-container\" data-vce-boxed-width=\"true\"><div class=\"vce-row vce-row--col-gap-30 vce-row-equal-height vce-row-content--top\" id=\"el-cd632848\" data-vce-do-apply=\"all el-cd632848\"><div class=\"vce-row-content\" data-vce-element-content=\"true\"><div class=\"vce-col vce-col--md-auto vce-col--xs-1 vce-col--xs-last vce-col--xs-first vce-col--sm-last vce-col--sm-first vce-col--md-last vce-col--lg-last vce-col--xl-last vce-col--md-first vce-col--lg-first vce-col--xl-first\" id=\"el-3912956e\"><div class=\"vce-col-inner\" data-vce-do-apply=\"border margin background  el-3912956e\"><div class=\"vce-col-content\" data-vce-element-content=\"true\" data-vce-do-apply=\"padding el-3912956e\"><div class=\"vce-text-block\"><div class=\"vce-text-block-wrapper vce\" id=\"el-88ee28dc\" data-vce-do-apply=\"all el-88ee28dc\"><h2 style=\"margin: 12.0pt 0cm 6.0pt 0cm;\"><span style=\"font-size: 15pt; font-family: inherit; color: #1a5276;\">PED Extraction Equipment Compliance Is the EU Market Entry Requirement That Determines Whether Your Equipment Can Be Legally Sold and Used in Europe<\/span><\/h2><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">PED extraction equipment compliance - compliance with EU Directive 2014\/68\/EU, the Pressure Equipment Directive - governs the design, manufacture, and conformity assessment of pressure-containing equipment placed on the EU market. For CO2 and ethanol extraction systems operating at 200\u2013500 bar across extraction vessels, separators, heat exchangers, and interconnecting pipework, PED compliance is non-negotiable. Every pressure-containing component above 0.5 bar maximum allowable pressure falls within PED scope. This guide explains how PED applies to extraction equipment, what the conformity assessment categories mean for buyers, and what documentation the Directive requires.<br><br><\/span><\/p><p>Discover Our <a href=\"https:\/\/www.buffaloextracts.com\/extraction-solutions.html\">Complete Extraction Solutions<\/a><\/p><h2 style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">What the Pressure Equipment Directive Covers<\/span><\/h2><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">EU Directive 2014\/68\/EU covers pressure equipment and assemblies with a maximum allowable pressure (PS) above 0.5 bar placed on the EU or EEA market. For extraction systems, this includes: extraction vessels, separators, and heat exchangers (pressure vessels); high-pressure CO2 lines and ethanol circuits (piping); pressure relief valves and rupture discs (safety accessories); and valves, fittings, and flow control devices (pressure accessories). An assembly - a functional combination of pressure equipment - is also covered as a whole where it presents an overall pressure hazard.<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">PED assigns equipment to one of four risk categories (I through IV) based on maximum allowable pressure (PS), volume or nominal diameter (V or DN), and the hazard class of the fluid. CO2 at extraction operating conditions and ethanol (flammable liquid) are Group 1 fluids - assessed more strictly than Group 2 fluids. High-pressure supercritical CO2 extraction vessels with significant volume typically reach Category III or Category IV, requiring Notified Body involvement in the conformity assessment.<\/span><\/p><p><a href=\"https:\/\/www.buffaloextracts.com\/co2-extraction.html\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1669 size-full\" src=\"https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application.png\" alt=\"cta\" width=\"1920\" height=\"800\" srcset=\"https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application.png 1920w, https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application-300x125.png 300w, https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application-1024x427.png 1024w, https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application-768x320.png 768w, https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application-1536x640.png 1536w, https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application-320x133.png 320w, https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application-480x200.png 480w, https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2025\/10\/Studio-Gradient_Buffalo-Extraction-Systems_Website-CTA-Module_Cannabis-Application-800x333.png 800w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/a><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-family: inherit;\"><span style=\"font-size: 11pt; color: black;\">PED compliance demonstrates conformity through CE marking and a Declaration of Conformity. Extraction equipment manufacturers supplying markets beyond the EU must address a broader <\/span><a href=\"https:\/\/www.buffaloextracts.com\/knowledge\/how-to-use-essential-oils-compliantly-across-global-markets-navigating-reach-ifra-and-fda-for-supercritical-extraction-products\/\"><span style=\"font-size: 11pt; color: #1155cc;\">global compliance<\/span><\/a><span style=\"font-size: 11pt; color: black;\"> landscape - REACH, IFRA, and FDA-adjacent regulatory requirements for products sold internationally create a multi-framework compliance obligation that CE-marked extraction equipment manufacturers increasingly address as part of their documentation package.<\/span><\/span><\/p><h2 style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">PED Risk Categories Applied to Extraction Equipment<\/span><\/h2><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">For extraction vessels in supercritical CO2 service, the combination of PS (200\u2013500 bar) and V (5\u2013100 litres per vessel in commercial extraction systems) places most commercial extraction vessels in Category III or IV, where Module G (individual unit verification) or Module H1 (full quality assurance with design examination) is the conformity assessment route. High-pressure pipework at extraction pressures falls under PED piping provisions - most high-pressure pipework in extraction systems reaches Category II or III depending on nominal diameter and operating pressure.<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-family: inherit;\"><span style=\"font-size: 11pt; color: black;\">At the highest PED risk categories, extraction equipment used in applications requiring <\/span><a href=\"https:\/\/www.buffaloextracts.com\/knowledge\/food-grade-essential-oils-for-pharmaceutical-and-nutraceutical-applications-purity-benchmarks-and-regulatory-hurdles\/\"><span style=\"font-size: 11pt; color: #1155cc;\">pharmaceutical standards<\/span><\/a><span style=\"font-size: 11pt; color: black;\"> - pharmaceutical-grade and nutraceutical-grade production with purity benchmarks and regulatory compliance requirements - faces both PED conformity assessment and GMP quality system requirements simultaneously. Pharmaceutical extraction equipment carries the most demanding combined regulatory burden in the food and life sciences sector, where CE marking under PED is the pressure integrity confirmation and GMP certification governs the quality system operating the equipment.<\/span><\/span><\/p><h2 style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">PED Compliant Extraction Equipment: The Conformity Assessment Process<\/span><\/h2><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">PED compliant extraction equipment is produced through a conformity assessment completed before CE marking is applied. For Category III and IV equipment, the manufacturer engages a Notified Body - an EU-accredited inspection and certification organisation such as DNV, T\u00dcV Rheinland, or Lloyd's Register. The Notified Body reviews the design, the manufacturing quality system, and\/or specific fabrication steps. Following conformity assessment, the manufacturer compiles the Technical File and signs a Declaration of Conformity identifying the manufacturer, equipment, applicable PED module, Notified Body, and authorised signatory.<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">CE marking is then applied to the equipment nameplate. For Category III and IV PED equipment, the four-digit Notified Body number appears immediately after the CE mark. The Technical File must be maintained and accessible to market surveillance authorities for a minimum of ten years from the date of last manufacture. For extraction systems additionally using flammable solvents, ATEX Directive 2014\/34\/EU applies separately - PED covers pressure integrity; ATEX covers explosion protection. Both require their own conformity assessment.<\/span><\/p><h2 style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">EU PED Extraction System: What Buyers Must Verify Before Purchase<\/span><\/h2><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">Buyers of PED extraction equipment for EU-market use should verify four things before purchase. First, CE marking is present on each pressure-containing component above 0.5 bar PS. Second, the Declaration of Conformity identifies the correct PED category and conformity assessment module. Third, for Category III or IV equipment, the DoC identifies the Notified Body by name and number. Fourth, the operating limits declared on the CE marking - maximum allowable pressure, maximum and minimum allowable temperatures - are consistent with the intended process conditions.<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-family: inherit;\"><span style=\"font-size: 11pt; color: black;\">Buyers evaluating PED compliant <\/span><a href=\"https:\/\/www.buffaloextracts.com\/knowledge\/choosing-the-right-essential-oils-extraction-machine-capacity-cost-and-roi-considerations\/\"><span style=\"font-size: 11pt; color: #1155cc;\">extraction machines<\/span><\/a><span style=\"font-size: 11pt; color: black;\"> - assessing capacity, cost, and ROI alongside PED certification status - should treat the Declaration of Conformity and Technical File as required documentation to review before commissioning, not administrative paperwork collected after installation. Equipment specification matching (operating pressure versus MAWP declared, temperature rating versus process conditions) must be confirmed at the pre-purchase stage, when correction is possible.<\/span><\/span><\/p><h2 style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">Where Buffalo Extraction Systems Fits In<\/span><\/h2><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">Buffalo Extraction Systems extraction equipment is CE, ASME, and PED certified; cryo-ethanol systems also ATEX certified; supplied with GMP documentation (USFDA, Health Canada, EU-GMP as required). This spans CO2 SCFE at 5L\u00d72, 25L\u00d72, and 100L\u00d72 configurations and cryo-ethanol systems at 5 kg, 20 kg, and 50 kg per batch. Each system runs SCADA that records instrument readings continuously throughout every batch, producing a time-stamped process record tied to the calibration state of the temperature sensors, pressure transducers, and flow meters feeding it. For a GMP calibration extraction facility, that relationship is foundational: the SCADA batch record is only as reliable as the instruments behind it, which is why calibration programme integrity is a prerequisite for meaningful process documentation rather than a parallel administrative requirement.<\/span><\/p><h2 style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">Conclusion<\/span><\/h2><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">PED extraction equipment compliance is the legally required demonstration that pressure-containing components placed on the EU market are fit for purpose at their rated pressure and temperature. For high-pressure CO2 and ethanol extraction systems, virtually all pressure-containing components require PED conformity assessment, and most vessels reach Category III or IV requiring Notified Body involvement. PED compliant extraction equipment carries CE marking and a Declaration of Conformity - these documents should be part of every EU extraction equipment purchase and retained for the life of the equipment.<\/span><\/p><h2 style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">Frequently Asked Questions<\/span><\/h2><p style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">What is the Pressure Equipment Directive and which extraction equipment does it cover?<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">EU Directive 2014\/68\/EU (PED) applies to pressure equipment and assemblies with a maximum allowable pressure above 0.5 bar placed on the EU\/EEA market. For extraction equipment, it covers all pressure-containing components: extraction vessels, separators, heat exchangers, high-pressure pipework, safety accessories (pressure relief valves, rupture discs), and pressure accessories (valves, fittings). The extraction system as an assembly is also covered if the combination of components presents a pressure hazard. Every pressure-containing component in a supercritical CO2 or ethanol extraction system requires PED conformity assessment before EU market placement.<\/span><\/p><p style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">What PED category does a supercritical CO2 extraction vessel fall into?<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">The PED category for a supercritical CO2 extraction vessel is determined by the combination of maximum allowable pressure (PS), vessel volume (V), and fluid hazard group. CO2 at extraction pressures (200\u2013500 bar) classified as Group 1 fluid, with vessel volumes typical in commercial extraction systems (5\u2013100 litres), results in most extraction vessels reaching Category III or IV - the categories requiring Notified Body involvement. Buyers should request the PED Category determination and conformity assessment module from the manufacturer for each vessel.<\/span><\/p><p style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">What documents must PED compliant extraction equipment include?<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">PED compliant extraction equipment must include: a Declaration of Conformity identifying the manufacturer, equipment, applicable PED directive reference, conformity assessment module, Notified Body name and number (for Category II, III, and IV equipment), and authorised signatory; permanent equipment markings including CE mark with Notified Body number (for Category III and IV), maximum allowable pressure in bar, maximum and minimum allowable temperatures, manufacturer name, and year of manufacture. The Technical File underpinning the DoC must be retained for ten years.<\/span><\/p><p style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">Does PED compliance expire or require periodic reassessment?<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">PED conformity assessment is a one-time pre-market assessment for a specific equipment design - it does not expire under PED itself. However, the equipment remains subject to national legislation on in-service inspection in each EU member state. Modifications or repairs to PED-compliant extraction equipment may require reassessment if they affect the pressure-containing components. EU member states implement Directive 2014\/68\/EU into national law and typically have parallel national legislation on in-service pressure vessel inspection intervals.<\/span><\/p><p style=\"margin-top: 10.0pt;\"><span style=\"font-size: 13pt; font-family: inherit; color: #1f618d;\">What is the difference between PED and ASME for extraction pressure vessels?<\/span><\/p><p style=\"margin: 0cm 0cm 6.0pt 0cm;\"><span style=\"font-size: 11pt; font-family: inherit; color: black;\">PED (EU Directive 2014\/68\/EU) is the EU market entry regulatory requirement for pressure equipment - it results in CE marking and a Declaration of Conformity. ASME BPVC Section VIII is a US fabrication standard for pressure vessels - it results in U-stamp certification and a Manufacturer's Data Report. Both can apply to the same vessel if the manufacturer has completed both conformity assessments; the two certifications are independent. ASME certification does not constitute PED compliance, and PED CE marking does not replace ASME certification requirements in US jurisdictions.<\/span><\/p><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>PED Extraction Equipment Compliance Is the EU Market Entry Requirement That Determines Whether Your Equipment Can Be Legally Sold and Used in EuropePED extraction equipment compliance &#8211; compliance with EU Directive 2014\/68\/EU, the Pressure Equipment Directive &#8211; governs the design, manufacture, and conformity assessment of pressure-containing equipment placed on the EU market. For CO2 and &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/\"> <span class=\"screen-reader-text\">PED Compliance for Extraction Equipment: A Simple Guide<\/span> Read More &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":1132,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2378","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>PED Extraction Equipment Compliance: A Simple Guide<\/title>\n<meta name=\"description\" content=\"A guide to PED compliant extraction equipment and PED extraction system compliance - EU Pressure Equipment Directive requirements, conformity assessment categories, and CE marking for CO2 and ethanol extraction machines in the EU market.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PED Extraction Equipment Compliance: A Simple Guide\" \/>\n<meta property=\"og:description\" content=\"A guide to PED compliant extraction equipment and PED extraction system compliance - EU Pressure Equipment Directive requirements, conformity assessment categories, and CE marking for CO2 and ethanol extraction machines in the EU market.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/\" \/>\n<meta property=\"og:site_name\" content=\"Buffalo Extraction System\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-21T15:12:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-21T15:13:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2023\/11\/BES_supercritical-fluid-extraction-process.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/\",\"url\":\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/\",\"name\":\"PED Extraction Equipment Compliance: A Simple Guide\",\"isPartOf\":{\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/#website\"},\"datePublished\":\"2026-08-21T15:12:41+00:00\",\"dateModified\":\"2026-08-21T15:13:31+00:00\",\"author\":{\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/#\/schema\/person\/3e7ac520197fbb367f332b811fde2fb8\"},\"description\":\"A guide to PED compliant extraction equipment and PED extraction system compliance - EU Pressure Equipment Directive requirements, conformity assessment categories, and CE marking for CO2 and ethanol extraction machines in the EU market.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.buffaloextracts.com\/knowledge\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PED Compliance for Extraction Equipment: A Simple Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/#website\",\"url\":\"https:\/\/www.buffaloextracts.com\/knowledge\/\",\"name\":\"Buffalo Extraction System\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.buffaloextracts.com\/knowledge\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/#\/schema\/person\/3e7ac520197fbb367f332b811fde2fb8\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.buffaloextracts.com\/knowledge\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8aa1e6e2996acb3e81fa4a0f998fa83ba725cb8468c7f746aff74d9051fef921?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8aa1e6e2996acb3e81fa4a0f998fa83ba725cb8468c7f746aff74d9051fef921?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\/\/www.buffaloextracts.com\/knowledge\"],\"url\":\"https:\/\/www.buffaloextracts.com\/knowledge\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PED Extraction Equipment Compliance: A Simple Guide","description":"A guide to PED compliant extraction equipment and PED extraction system compliance - EU Pressure Equipment Directive requirements, conformity assessment categories, and CE marking for CO2 and ethanol extraction machines in the EU market.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/","og_locale":"en_US","og_type":"article","og_title":"PED Extraction Equipment Compliance: A Simple Guide","og_description":"A guide to PED compliant extraction equipment and PED extraction system compliance - EU Pressure Equipment Directive requirements, conformity assessment categories, and CE marking for CO2 and ethanol extraction machines in the EU market.","og_url":"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/","og_site_name":"Buffalo Extraction System","article_published_time":"2026-08-21T15:12:41+00:00","article_modified_time":"2026-08-21T15:13:31+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-content\/uploads\/2023\/11\/BES_supercritical-fluid-extraction-process.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/","url":"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/","name":"PED Extraction Equipment Compliance: A Simple Guide","isPartOf":{"@id":"https:\/\/www.buffaloextracts.com\/knowledge\/#website"},"datePublished":"2026-08-21T15:12:41+00:00","dateModified":"2026-08-21T15:13:31+00:00","author":{"@id":"https:\/\/www.buffaloextracts.com\/knowledge\/#\/schema\/person\/3e7ac520197fbb367f332b811fde2fb8"},"description":"A guide to PED compliant extraction equipment and PED extraction system compliance - EU Pressure Equipment Directive requirements, conformity assessment categories, and CE marking for CO2 and ethanol extraction machines in the EU market.","breadcrumb":{"@id":"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.buffaloextracts.com\/knowledge\/ped-compliance-extraction-equipment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.buffaloextracts.com\/knowledge\/"},{"@type":"ListItem","position":2,"name":"PED Compliance for Extraction Equipment: A Simple Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.buffaloextracts.com\/knowledge\/#website","url":"https:\/\/www.buffaloextracts.com\/knowledge\/","name":"Buffalo Extraction System","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.buffaloextracts.com\/knowledge\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.buffaloextracts.com\/knowledge\/#\/schema\/person\/3e7ac520197fbb367f332b811fde2fb8","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.buffaloextracts.com\/knowledge\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8aa1e6e2996acb3e81fa4a0f998fa83ba725cb8468c7f746aff74d9051fef921?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8aa1e6e2996acb3e81fa4a0f998fa83ba725cb8468c7f746aff74d9051fef921?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/www.buffaloextracts.com\/knowledge"],"url":"https:\/\/www.buffaloextracts.com\/knowledge\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/posts\/2378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/comments?post=2378"}],"version-history":[{"count":2,"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/posts\/2378\/revisions"}],"predecessor-version":[{"id":2380,"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/posts\/2378\/revisions\/2380"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/media\/1132"}],"wp:attachment":[{"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/media?parent=2378"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/categories?post=2378"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.buffaloextracts.com\/knowledge\/wp-json\/wp\/v2\/tags?post=2378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}